When using a centrifuge a medical assistant must do the following to ensure safety and accuracy?

Centrifuges can create aerosols and this must be considered with each use. The necessary precautions taken will depend upon what is being used. If hazardous materials such as carcinogens, highly toxic, or infectious agents will be placed in a centrifuge, then precautions must be taken to prevent an exposure of lab personnel to aerosols or liquids.

Improper care of a centrifuge and its components can lead to exposure to hazardous substances, injuries, damaged equipment and lab space, and a loss of research, money, and time.

Types

  • Microcentrifuge ~15,000 rpm
  • Low/High speed 2,000 – 20,000 rpm
  • Ultracentrifuges ~120,000 rpm

Hazards

  • Mechanical failure of the machine
  • Lab equipment failure (tubes, etc.)
  • Aerosol generation
  • Operator Error

Operating Procedures

  • Follow all the manufacturer’s instructions for care.
  • Develop and implement a strict cleaning, storing, and maintenance protocol.
  • Only use manufacturer compatible centrifuge, rotor, buckets, caps, and adapters.
  • Replace centrifuge parts including bottles, tubes, and O-rings at the first sign of damage.
  • Assemble the bottles, buckets, and rotor per the manufacturer’s instructions.
  • Tightly seal all tubes and safety cups.
  • Close lid during operation.
  • Allow to come to complete stop before opening.

Safe Operation

  • Use safety cups whenever possible.
  • Disinfect or clean weekly and after all spills or breakages.
  • Lubricate O-rings and rotor threads weekly.
  • Do not operate the centrifuge without the rotor properly balanced.
  • Do not use rotors that have been dropped.
  • Inspect the speed disk for sign of damage if using an ultra-speed unit and discontinue use if damaged.
  • Inspect the rotor and tube cavities for signs of damage and discontinue use if damaged.
  • If using a swinging bucket rotor, follow these additional workplace practice controls:
    • Ensure all metal buckets are in place.
    • Use matching buckets, caps, and adapters
    • Load symmetrical to axis of rotation and to pivotal axis within the manufacturer's recommended load tolerance.
    • Ensure buckets are properly seated to the rotor and the rotor is properly attached to the centrifuge spindle.
  • If using a fixed angle rotor, follow these additional workplace practice controls:
    • Tighten rotor lid correctly.
    • Properly install and attach rotor to spindle.
    • Gently pull up on the rotor to confirm rotor is attached.
  • Contact your centrifuge representative for specific information.

If you suspect leakage occurred from the centrifuge, leave the area, do not open the centrifuge for at least 30 minutes to allow aerosols to settle, then access situation while wearing appropriate personal protective equipment (PPE) and taking necessary precautions. Contact EHS at (512) 471-3511 as necessary for assistance.

All information about When Using A Centrifuge A Medical Assistant

At dayofdifference.org.au you will find all the information about When Using A Centrifuge A Medical Assistant. We have collected a lot of medical information. Check out the links below.


When using a centrifuge a medical assistant must do

    https://www.coursehero.com/file/p3ik0hu3/When-using-a-centrifuge-a-medical-assistant-must-do-which-of-the-following-to/
    When using a centrifuge a medical assistant must do. School Potomac High School; Course Title SOCIAL STUDIES 111; Uploaded By SargentPorcupinePerson433. Pages 27 This preview shows page 23 - 25 out of 27 pages. View full document. See Page 1 ...


when using a centrifuge, a medical assistant

    https://pommiemommie.com/7gqawh/when-using-a-centrifuge%2C-a-medical-assistant
    Which of the following terms should a medical assistant use to tell a provider that a patient is having discomfort and difficulty breathing? Which of the following actions should the medical assistant take first? Students in the Medical Program learn about the challenging and life-changing opportunities available in this fi eld. Example: "During my career as a medical …


when using a centrifuge, a medical assistant

    http://hvaplatt.se/wutzuk/when-using-a-centrifuge%2C-a-medical-assistant
    In which of the following positions should the assistant place the patient for this procedure? Found inside – Page 401The separation of cellular elements from blood plasma can be speeded up by using a centrifuge . After centrifugation : Ans = A 1. The plasma rises to the top . 2. The red cells fall to the bottom . 3. The white cells settle to the ... Which of the following cardiac …


    https://blink.ucsd.edu/safety/research-lab/laboratory/centrifuge.html
    Fill and open centrifuge tubes, rotors, and accessories in a biological safety cabinet (BSC). Use sealed tubes and safety buckets that seal with O-rings. Before each use inspect tubes, O-rings, and buckets for cracks, chips, erosions, bits of broken glass, etc. Do not use aluminum foil to cap centrifuge tubes—it may detach or rupture during ...


Pretest CCMA study Flashcards - Quizlet

    https://quizlet.com/375500479/pretest-ccma-study-flash-cards/
    When using a centrifuge, a medical assistant must do which of the following to ensure safety and accuracy? Place the zero mark of the measuring tape against the infant's forehead. ... A medical assistant is examining the skin of a patients forearm where the patient reports developing a rash. The assistant notes multiple solid elevations that ...


Centrifuges | Environmental Health & Safety (EHS) | The …

    https://ehs.utexas.edu/working-safely/equipment-safety/centrifuges
    If you suspect leakage occurred from the centrifuge, leave the area, do not open the centrifuge for at least 30 minutes to allow aerosols to settle, then access situation while wearing appropriate personal protective equipment (PPE) and taking necessary precautions. Contact EHS at (512) 471-3511 as necessary for assistance.


6 Safety Tips for Operating a Centrifuge - Lab Manager

    https://www.labmanager.com/lab-health-and-safety/6-safety-tips-for-operating-a-centrifuge-19835
    There are a few important guidelines for operating a centrifuge, even a small one. Following them can prevent damage to the centrifuge and possible serious injury to you and others. 1. The work surface must be level and firm. Do not use the centrifuge on an uneven or slanted work surface. 2. Balance the tubes in the rotor!


Which of the following techniques should a medical assistant use to confirm a patient's?

Which of the following techniques should a medical assistant use to confirm a patient's understanding of insulin administration? Observe the patient as she performs a self-demonstration. A medical assistant is explaining to a female patient how to collect a clean-catch urine specimen.

Which of the following steps should a medical assistant take to follow aseptic guidelines when administering injections?

Which of the following steps should a medical assistant take to follow aseptic guidelines when administering injections? Wipe injection site with an alcohol pad.

Which of the following actions should a medical assistant take to verify the quality of venipuncture?

Which of the following actions should a medical assistant take to verify the quality of venipuncture supplies before beginning a blood draw? Inspect the integrity of the needle's seal.

Which one of the following terms should a medical assistant use to tell a provider that a patient is having discomfort and difficulty breathing?

Which of the following terms should a medical assistant use to tell a provider that a patient that a patient is having discomfort and difficulty breathing? Dyspnea is a term used to indicate that a patient is experiencing difficult or painful breathing.